⚡ warmtepomp optimalisatie ⚡ heat pump optimizer
Gebouwd na 1990
C = 1.1 W/m³·°C
ΔT=31K (21/-10)
minimaal WP vermogen
minimum heat pump capacity
13.6kW
| type | type | C | 300m³ | 400m³ | 500m³ |
|---|---|---|---|---|---|
| oud geen isol | old no insul | 2.0 | 18,6 | 24,8 | 31,0 |
| oud met isol | old with insul | 1.5 | 14,0 | 18,6 | 23,3 |
| na 1990 | after 1990 | 1.1 | 10,2 | 13,6 | 17,1 |
| na 2000 | after 2000 | 0.9 | 8,4 | 11,2 | 14,0 |
📈 stooklijn (bivalent)
📈 heating curve (bivalent)
-10°C
⚡ kantelpunt ⚡ balance point -3.5°C
+20°C
—— heat loss · · · HP capacity
📊 bèta – jaarlijkse dekking
📊 beta – annual coverage
β=1.0 → 100%
β=0.6 → 94%
β=0.9 → 98%
β=0.5 → 92%
β=0.8 → 97%
β=0.4 → 91%
β=0.7 → 95%
β=0.3 → 88%
huidige β=0.40 → 91% WP
💡 het kantelpunt is de buitentemp waar WP vermogen = warmteverlies.
💡 balance point = outdoor temp where HP capacity = heat loss.