⚡ warmtepomp optimalisatie ⚡ heat pump optimizer

📐 inhoud (m³) 📐 volume (m³) 290 m³
Gebouwd na 1990
C = 1.1 W/m³·°C ΔT=31K (21/-10)
minimaal WP vermogen minimum heat pump capacity 13.6kW
🔹 β-factor (WP / warmteverlies) 🔹 β-factor (HP / heat loss) 0.40
kleine WP (0.2)small HP (0.2) gelijk aan verlies (1.0)equal to loss (1.0)
⚙️ gekozen WP vermogen = ⚙️ selected HP capacity = 5.60 kW
typetypeC300m³400m³500m³
oud geen isolold no insul2.018,624,831,0
oud met isolold with insul1.514,018,623,3
na 1990after 19901.110,213,617,1
na 2000after 20000.98,411,214,0

📈 stooklijn (bivalent)

📈 heating curve (bivalent)

-10°C ⚡ kantelpunt ⚡ balance point -3.5°C +20°C

—— heat loss · · · HP capacity

📊 bèta – jaarlijkse dekking
📊 beta – annual coverage
β=1.0 → 100%
β=0.6 → 94%
β=0.9 → 98%
β=0.5 → 92%
β=0.8 → 97%
β=0.4 → 91%
β=0.7 → 95%
β=0.3 → 88%

huidige β=0.40 → 91% WP

💡 het kantelpunt is de buitentemp waar WP vermogen = warmteverlies. 💡 balance point = outdoor temp where HP capacity = heat loss.